Compliant with MIL-STD 810G, MIL-STD 461F/E (option) and IP65
|
 |
 |
 |
 |
M970 is resistant to: |
M970 is resistant to: |
M970 can withstand: |
M970 can have: |
• hot temperature
• low temperature
• temperature shock
• sand, dust
• low pressure
|
• water
• high humidity
• salt fog
|
• vibration
• drops
|
• optional EMI
protection
|
|
Category |
Mil Scpec Test/Method |
Altitude: Operating |
MIL-STD-810G / Method 500.5 / Procedure I
• 0 ~ 15,000ft
|
Altitude: Non-Operating |
MIL-STD-810G / Method 500.5 / Procedure II
• 0 ~ 15,000ft
|
Dust: Non-Operating |
MIL-STD-810G / Method 510.5 / Procedure I
• Particle size: smaller than 75 um, (<149um)
• Density 20 g/cm3
|
Dust: Non-Operating |
IEC 60529 Edition 2.1: 2001-02-IP6X
• Type of dust : Talcum powder
• The amount of dust : 2 Kg
|
Humidity: Non-Operating |
MIL-STD-810G / Method 507.5/ Procedure II
• Storage humidity=95%RH
• 10 Cycles, 20°C to 60°C
|
Humidity: Operating |
MIL-STD-810G / Method 507.5/ Procedure II
• Operating humidity=95%RH
• 10 Cycles, 20°C to 60°C
|
High Temp: Non-Operating |
MIL-STD-810G / Method 501.5 / Procedure I
• 60°C
|
High Temp: Operating |
MIL-STD-810G / Method 501.5 / Procedure II
• 60°C
|
Low Temp: Operating |
MIL-STD-810G / Method 502.5 / Procedure II
• minus 20°C
|
Low Temp: Non-Operating |
MIL-STD-810G / Method 502.5 / Procedure I
• minus 20°C
|
Temperature Shock: Operating |
MIL-STD-810G / Method 503.5 / Procedure I
• From 60°C to minus 30°C (3 cycles)
|
General Vibration: Operating |
MIL-STD-810G / Method 514.6 / Procedure I
• Power spectral density ranges=0.0007 to 0.5120 G2/Hz
• Frequency ranges=5 to 500 MHz
|
General Vibration: Non-Operating |
MIL-STD-810G / Method 514.6 / Procedure I-category 24
• 0.04G2/Hz 20-1000 Hz, Descending 6dB/Oct to 2000 Hz
|
Drop: Transit Drop 48-inch, Non-operating |
MIL-STD-810G / Method 516.6 / Procedure IV
• 26 times 91 cm height free drop onto Plywood on
• concrete (8 corners, 12 edges and 6 faces Total 26 drops)
|
Vehicle Vibration: Operating |
ASTM D4169-04 (99) Schedule E, truck Assurance Level II, Operating
• Power spectral density ranges=0.00001 to 0.01 G2/Hz
• Frequency ranges=1 to 200 MHz
|
Water Resistance: IEC |
IEC 60529 Edition 2.1: 2001-02-IPX5
|
Water Resistance: MIL-STD |
MIL-STD-810G / Method 506.5 / Procedure II
• 10 mins per axis, 6 axis
• Rain chamber no less than 40 PSI and no less than 4 hrs
|
Salt Fog : Non-operating |
MIL-STD 810G/Method 509.5 Procedure I
• 5% saline exposure for 48hr exposure period and 48hr drying period
• 95F exposure temperature
|